In this study, droplet microfluidic technology is used to prepare nSi/NC/CL-20 composite microspheres with regular shape, good dispersibility and uniform particle size. Studies show that the addition of nano-silicon powder (nSi) can significantly...
Artikel
Non‐Enzymatic Electrochemical Sensor for Nanomolar Detection of Propyl Gallate in Food Samples Using (2D/0D) MXene/CdTe QDs Nanocomposites
Von Wiley-VCH zur Verfügung gestellt
Electrochemical sensor based on CdTe QDs/Ti3C2Tx (MXene) was developed for the sensitive and selective detection of propyl gallate (PG) in food samples. The sensor demonstrated excellent sensitivity (0.465 µA µM−1 cm−2), a low detection limit (52 nM), and a wide linear range (0.1-1000 µM). It also exhibited high stability, good repeatability (RSD = 1.36%), and effective performance in real-sample analysis. This study presents a promising approach for monitoring antioxidant residues in food safety applications.
Abstract
Antioxidants such as propyl gallate (PG) are commonly used to extend the shelf life of processed foods by preventing rancidity. However, excessive intake of PG can cause adverse health effects, including dermatitis and renal damage, underscoring the necessity for its effective monitoring and removal. In this study, we have developed an electrochemical sensor for PG detection based on cadmium telluride (CdTe) quantum dots (QDs) integrated titanium carbide (Ti3C2Tx, MXene). The CdTe QDs/Ti3C2Tx nanocomposite demonstrated significantly higher peak current intensity compared to other modified electrodes, as confirmed by cyclic voltammetry. The synergistic interaction between CdTe QDs and Ti3C2Tx enhanced the PG detection with a high sensitivity (0.465 µA µM−1cm−2), low detection limit (52 nM), and wide linear range (0.1–1000 µM). Benefiting from a high surface area and efficient electron transfer, the CdTe QDs/Ti3C2Tx nanocomposite exhibited excellent repeatability, reproducibility and storage stability over 10 days, with relative standard deviation (RSD) of 1.36%. The practical applicability of the proposed electrochemical sensor was validated through real-time monitoring of PG in food samples, including chicken meat and noodle extracts. The standard addition method in real samples demonstrated a satisfactory recovery rate, highlighting the sensor's potential as a reliable tool for PG detection in food safety monitoring.
Zum VolltextÜberprüfung Ihres Anmeldestatus ...
Wenn Sie ein registrierter Benutzer sind, zeigen wir in Kürze den vollständigen Artikel.